CAR70M
70 Watt medical automobile power adapter
- 넓은 입력 전압 범위 10-32V
- 최대 출력 전력 70 Watt
- 환자 안전을 최대 고려한 Galvanic isolation
- 요청 시 개별 출력 커넥터
- 자동차/트럭 입력 커넥터
- 벽걸이 키트 옵션
더 많은 정보를 찾고 계십니까?
Downloads CAR70M
CAR70M
Specification
| Input | |
|---|---|
| Voltage range | 10.00 - 32.00VDC | 
| Standby current | Typical 37.00mA @ 10.00V input Typical 29.00mA @ 32.00V input | 
| Input fuse | 10.00A | 
| Protection | Reverse polarity (input fuse), Under voltage protection (Transient suppression circuit) | 
| Output | |
|---|---|
| Voltage range | 16.00 - 19.00V nominal | 
| Power | 66.00W cont. | 
| Initial set tolerance | ±3% max. | 
| Load regulation | -4% max. | 
| Line regulation | ±1% max. | 
| Ripple & noise | < 0.12V pk-pk | 
| Current limit | Constant current | 
| Protection | Short circuit | 
| Environmental | |
|---|---|
| Cooling | Convection cooled | 
| Temperature | Operating: -20°C to 40°C (40°C to 50°C, derating 35%) | 
| Pressure & altitude | Operating: 1200hPa to 570hPa (max. 4600m above sea level) | 
| Humidity | 5 to 95% r.H., non condensing | 
| General | |
|---|---|
| Galvanic isolation | Isolation voltage 2.00kV | 
| Input connector | Cigarette lighter adapter | 
| Output connector | Customer-specific | 
| Efficiency | typical 88% at 100% load | 
| MTBF | > 100000h @ 25°C ambient temperature and GB per MIL-HDBK217F Humidity | 
| Green procurement | RoHS 2011/65/EU + 2015/863/EU REACH 1907/2006 WEEE 2012/19/EU | 
| Indicator | Single green LED | 
| Ingress protection rating | IEC60529, IP42 | 
| Regulatory approvals | Europe | CE | 
| United Kingdom | UKCA | |
| International | CB Report IEC 60601-1 2nd edition | |
| USA & Canada | UL60601-1 | |
| Electromagnetic emissions | Europe | EN 55011/55022 class B | 
| USA & Canada | FCC15 class B | |
| Medical electrical equipment | IEC60601-1-2 | |
| Electromagnetic immunity | ESD immunity | IEC61000-4-2, 8kV contact/15kV air | 
| Electromagnetic field immunity | IEC61000-4-3, 80-2700MHz, 30V/m, modulation 80%/200Hz | |
| Electrical fast transient/burst immunity test | IEC61000-4-4, +/-2kV, 5/50ns | |
| Surge immunity test | IEC61000-4-5, +/-0.5kVsym, 1.2/50(8/20)μs | |
| Conducted Immunity | IEC61000-4-6, 0.15-80MHz, 10V, 80%, 1KHz, AM, with CDN | |
| ISO-Impulses | ISO7637-2, pulse 1 till 5, immunity test level III | |
| Medical electrical equipment | IEC60601-1-2 | |
| UNECE vehicle regulation | E13 ECE Reg. 10 | 
- Other approvals on request
| Housing dimensions (LxWxH) | 160.00 x 59.00 x 34.00mm, without cables and connectors | 
| Input cable length | 240cm ±5% | 
| Output cable length | 100cm ±5% | 
| Weight | approx. 350g, without cables, connectors and wall-mount kit | 
CAR70M is approved worldwide