RRC-SMB-UBC-DIS
Standard Battery conditioner for SMBus compatible Batteries
- Ensures batteries are discharge to 30% state of charge (or less) for transportation
- Places batteries in very low power mode called “ship mode” to limit self-discharge
- For the standard battery form factors RRC20xx or smart batteries with a similar footprint
- Simple operation – Plug and Play
- Automatic recognition and calibration of smart battery learned capacity
- External power supply for worldwide use
- Country specific AC input cables available
- Optional DC/DC car adapter available
Are you looking for more information?
RRC-SMB-UBC-DIS
Specification RRC-SMB-UBC-DIS
| Input | |
| Voltage range | 19.00 – 26.00VDC |
| Current | 3.40A max. |
| Power | 65.00W |
| Protection | Over current (fuse protected), under voltage |
| Output | |
| Voltage range | 0 - 17.40VDC |
| Current range | 0 - 4.80A |
| Voltage tolerance | ±1% max. |
| Current tolerance | ±10% max. @1.00A, ±3% max. @4.00A |
| Charge power | 60.00W max. |
| Protection | Short circuit, over temperature shutdown, input-/output over current |
| Environmental | ||
| Operation: | Storage: | |
| Ambient Temperature | 0°C to 40°C | -30°C to 80°C |
| Pressure and Altitude | 1060hPa to 533hPa -382m to 5000m | 1060hPa to 533hPa -382m to 5000m |
| Humidity (non-condensing) | 8% to 90% r.H. | 5% to 95% r.H. |
| General | |
| Efficiency | ~95% at 100% load |
| Indicator | Multi-color LED (green, red, orange) |
| Battery types | Standard battery form factors RRC20x or smart batteries with a similar footprint |
| Green procurement | RoHS 2011/65/EU + 2015/863 REACH 1907/2006 WEEE 2012/19/EU Chinese RoHS |
| Cooling | Convection cooled |
| One time Red/Orange/Green | Self-test: Charger is ready for use. |
| Green/Red blinking | Charger identifies inserted battery. |
| Orange | Progress indication – The battery is being charged. |
| Orange blinking | Progress indication – The battery is being discharged. |
| Green | Success indication - The battery successfully charged/discharged to transport State of Charge and is set into ship mode. |
| Red | Error indication - The battery was not successfully charged/discharged to transport State of Charge or is not set into ship mode. |
| Red blinking | The temperature of the battery is too low or too high. |
| Housing dimensions (LxWxH) | 151 x 90 x 43mm |
| Weight | 198g (excluding power supply) |
In combination with included external AC/DC power supply
| Regulatory approvals | Europe | EN62368-1 (CE) |
| International | IEC62368-1 (CB) | |
| Electromagnetic Emissions | Europe | EN55011, EN55032, level B |
| USA | FCC15 class B | |
| Electromagnetic Immunity | ESD immunity | EN/IEC61000-4-2 |
| Electromagnetic field immunity | EN/IEC61000-4-3 | |
| EFT / Burst | EN/IEC61000-4-4 | |
| Surge | EN/IEC61000-4-5 | |
| Conducted Immunity | EN/IEC61000-4-6 | |
| Magnetic Fields | EN/IEC61000-4-8 | |
| Voltage dips, short instrumentations & volt-age variations | EN/IEC61000-4-11 | |
| Immunity characteristics | EN55024 |
Specification external AC/DC power supply
| Input | |
| Voltage range | 100.00 – 240.00VAC ±10%, 50-60Hz |
| Current | 1.70A max. |
| Stand by power | < 0.21W @ no load |
| Output | |
| Voltage range | 19.00VDC ± 10% |
| Power | 65.00W max. |
| Current range | 3.40A max. |
| Protection | Short circuit, over voltage, over current, over temperature |
| Efficiency | California's Energy Efficiency Level VI |
| Ripple & Noise | 0.30V (p-p) |
| Standard output connector | DC barrel jack, 5.5 x 2.5mm |
| Housing dimensions (LxWxH) | 95 x 50 x 25.4mm |
| Weight | 270g |
| Cable length | 1600mm |
| Approvals | Europe | CE |
| International | CB | |
| USA & Canada | cULus | |
| Australia & New Zealand | RCM | |
| Russia (Customs Union) | EAC | |
| Korea | KC | |
| China | CCC | |
| Japan | PSE | |
| India | BIS | |
| Taiwan | BSMI | |
| Mexico | NOM | |
| Argentina | IRAM | |
| South Africa | SABS | |
| Singapore | Safety Mark | |
| United Kingdom | UKCA | |
| Morocco | CMIM |